Skip to main content

Solar-Charging Gateways troubleshooting

This article focuses on diagnosing issues related to the Solar-charging gateways charger.

Miltiadis Xinopoulos avatar
Written by Miltiadis Xinopoulos
Updated over 2 years ago

If this is the first time you are using the equipment please read the following guides:
a. How to assemble and activate your gateway
b. How to activate and discover your sensors and your repeaters, and,
c. How to discover your devices on the platform.**

This article assumes that you have read through "I am losing sensor readings"

  • Is the Solar-Charger operational?
    Step 1: Locate and open the gateway outer casing.
    Step 2: Visually inspect the Chargers indicator lights (Click here for reference). Under normal operation one of the three colored lights should be solidly lit at a time.

Operation mode

Blue LED

Yellow Led

Green Led

Not charging

Blinking

off

off

Bulk charging

Solidly Lit

off

off

Absorption

off

Solidly Lit

off

Float

off

off

Solidly Lit

  • Is the Solar-Charger displaying an error?
    Step 1: Locate and open the gateway outer casing.
    Step 2: Visually inspect the Chargers indicator lights (Click here for reference).

    Operation mode

Operation mode

Blue LED

Yellow Led

Green Led

The chargers temperature is too high

off

off

Blinking

Charger over-current

Blinking

off

off

Charger or panel over-voltage

off

Blinking

off