On a MG\SP

  • The Olarm bypasses the Panel programming and sends a .8 second pulse\latch

On EVO192

  • The Olarm follows the Programming of the panel, so the PGM needs to be set as a Utility Key

    • Do required programming on panel.

    • Then go to the App - Settings - Utility Key - Set Amount

    • tap Save - then go into the Utility key

    • Toggle Enable and tap save.