Skip to main content
All CollectionsSpecific Laser & Wavelength FAQsYAG and 1060nm-1080nm
How do I select the appropriate laser safety window for a 200W fiber laser engraver/cutter with a 1064nm wavelength?
How do I select the appropriate laser safety window for a 200W fiber laser engraver/cutter with a 1064nm wavelength?
Updated over a week ago

Always consult your on-site Laser Safety Officer (LSO) for specific guidance. Required optical density (OD) and laser safety personal protective equipment (PPE) are determined based on worst-case scenarios and require professional judgment. All laser safety equipment provided is intended for diffused beam viewing only.

In most cases, the manufacturer will specify the required optical density for a laser safety window. If not, you can determine the appropriate optical density for your window by considering the wavelength and power of your laser and referring to ANSI standards.

For a 200W fiber laser with a 1064nm wavelength, we recommend one of the following products:

100-435-000: Laser Safety Window
​Optical Density (OD):

OD 5+ @ 190-375 nm

OD 5+ @ 860-1095 nm

OD 6+ @ 1064 nm

OD 5+ @ 10,000-11,000 nm

100-420-000: Laser Safety Window
​Optical Density (OD):

OD 5+ @ 190-375 nm

OD 5+ @ 880-1120 nm

OD 6+ @ 1064 nm

OD 5+ @ 10,000-11,000 nm

Did this answer your question?