Purpose:
Service Mode allows access to advanced diagnostic tools, flowmeter calibration, temperature monitoring, and hardware-level configurations for PS2 systems. Service mode can be accessed in any sw version (although older software versions may call it "technician mode")
⚠️ Important Note:
Only enter Service Mode when instructed by a Poursteady technician. Changes made in Service Mode can override user recipes and core system behavior.
Prerequisites:
Poursteady PS2 is powered on and fully booted
Access to the UI panel
No active brews or service operations in progress
Main Process:
1. Navigate to Service Mode
On the PS2 UI panel, tap the Settings icon
Scroll down and select Machine Info
Continue scrolling until you find the Service Mode option
2. Enable Service Mode
Tap Service Mode, then confirm when prompted:
“Are you sure you want to enable Service Mode?”Once activated:
The Service Mode icon will appear in the top-right corner of the UI
New advanced settings will become visible under the Settings menu
🧠 Service Mode Enables:
FM Calibrate: Flowmeter calibration tool
Live temperature readout during pours
Access to hardware test recipes (e.g.,
Tech FM Cal)Additional diagnostics and real-time system metrics
3. Exit Service Mode
Once your diagnostics or calibration is complete:
Return to Settings → Machine Info
Scroll to Service Mode
Tap Disable
The system will return to standard UI behavior, restoring all saved user recipes and brew modes
Success Confirmation:
Service Mode icon appears when enabled and disappears when disabled
Advanced settings only accessible in Service Mode are hidden once exited
Normal brewing functionality resumes without interruption