The following guide describes how to configure the Modbus TCP
settings for SMA inverters and how to test the connection.
Prerequisites
Required Items
WiFi-capable device (smartphone, tablet, or laptop)
Inverter
serial number
WPA2-PSK
password (located on inverter label)Installer
rights for certain settings
Configuration Process
Initial Connection
Choose one of these connection methods:
WiFi Connection
Find network named
SMA19xxxxxxx
Use IP address:
192.168.12.3
Ethernet Connection
Connect via ethernet cable
Use IP address:
169.254.12.3
Settings Configuration
Open web browser
Enter appropriate
IP
address based on connection methodLog in as
Installer
Navigate to
Device Parameters
Select
Edit Parameters
Modbus Setup
Navigate to
Modbus
settingsEnable the Modbus feature
Enable
TCP server
Leave the port as
502
Grid Connection Configuration
For standard models:
Go to
System and device control
Find
Grid connection point
Change
Operating mode of active power limitation
toExternal
For SBx.x-1AV40/41
models:
Locate
Operating mode active power setting
Set to
External active power setpoint
Finalizing Changes
Always click
Save All
after making modificationsWait for changes to be applied
Troubleshooting
Modbus Setting Issues
If unable to change Modbus settings:
Contact your installer
Check if settings are locked by
SMA Grid Guard
Verify
installer
access rights
Connection Problems
If experiencing connection issues:
Verify correct WiFi network selection
Double-check
IP
addressEnsure you're within range of the inverter
Missing Settings
If settings are not visible:
Verify your model number
Check for alternative setting names
Confirm
installer
access level
Testing Connectivity (advanced)
After enabling Modbus TCP on your SMA inverter, you should verify that the connection is functioning correctly. You can follow our testing guide to confirm the connection. For SMA inverters, use the default Modbus port 502. The Unit ID is typically set to 3, which differs from many other manufacturers. Make sure you've completed all the grid connection configuration steps before testing, as these settings can affect Modbus communication.