AXIS Sensors - Vemcount Firewall Guide
Purpose: This guide outlines the outbound firewall and network access required for AXIS sensors to communicate correctly with Vemcount services.
Important: All firewall rules should be configured for outbound connections only. DNS resolution for the listed hostnames should also be allowed.
Required network access
Service | Hostname / URL | Port(s) | Purpose |
MQTT data connection | mqtt.vemcount.com | 1883 | Transmission of AXIS Object Analytics event data to Vemcount via MQTT |
Time synchronization | ntp.vemcount.com | 123/UDP | Time sync for stable and accurate operation |
License validation | license.vemcogroup.com | 443 | License checks and validation where relevant in the Vemcount environment |
AXIS setup note: In AXIS Object Analytics set the MQTT host to mqtt.vemcount.com and port 1883. The MQTT username and password are sent to you by Vemco support when your sensors are registered. Enable event interval in the AXIS application, and make sure the sensor MAC address is added in Vemcount before counting starts.
Additional setup notes
Configure AXIS Object Analytics to send data over MQTT to
mqtt.vemcount.comon port1883.Ask Vemco support for the MQTT login for your installation. Never share it outside your installation team.
Enable event interval in the AXIS application so event counts are sent correctly.
Add the sensor MAC address in Vemcount before the counting starts.
Main Vemcount IP addresses
18.195.189.44
15.197.146.64
3.33.145.212