Brickstream Sensors - Vemcount Firewall Guide
Purpose: This guide outlines the outbound firewall and network access required for Brickstream sensors to communicate correctly with Vemcount services.
Important: All firewall rules should be configured for outbound connections only. DNS resolution for the listed hostnames should also be allowed.
Required network access
Service | Hostname / URL | Port(s) | Purpose |
Device administration / remote connection | brickstream.vemcount.com | 3000 | Remote access and administration of Brickstream sensors |
Data push | data.vemcount.com | 80, 443 | Transmission of sensor data to Vemcount |
Time synchronization | ntp.vemcount.com | 123/UDP | Time sync for stable and accurate operation |
License validation | license.vemcogroup.com | 443 | License checks and validation |
Optional / legacy note: The official Vemcount firewall guideline also lists port 440 for older devices that cannot handle TLS above v1.0, plus additional services such as MQTT, FTP upload, VPN, and other device-specific endpoints. These are normally not required for a standard Brickstream setup unless specifically requested.
Main Vemcount IP addresses
18.195.189.44
15.197.146.64
3.33.145.212
Brickstream / Vemcount network requirements
Use the required outbound rules above when configuring network access for Brickstream sensors in a standard Vemcount setup.
If a Brickstream sensor is online but Vemcount receives no data
After a platform update in October 2026, a few Brickstream sensors stopped communicating with Vemcount although the network rules above were in place. The cause was the sensor's SNI host setting for the HTTPS data push, which had to be adjusted on the sensor. If a Brickstream sensor is reachable on the local network but Vemcount shows it offline or without data, contact support@vemcogroup.com with the sensor ID and the last seen time: we check the data push settings, including the SNI host, and adjust them.