Purpose: This guide outlines the outbound firewall and network access required for TDI sensors to communicate correctly with Vemcount services.

Important: All firewall rules should be configured for outbound connections only. DNS resolution for the listed hostnames should also be allowed.

Required network access

Service

Hostname / URL

Port(s)

Purpose

Data push (HTTP)

data.vemcount.com/ss/tdi

80

Transmission of sensor data to Vemcount using HTTP push

Data push (HTTPS)

data.vemcount.com/ss/tdi

443

Transmission of sensor data to Vemcount using HTTPS push

Time synchronization

ntp.vemcount.com

123/UDP

Time sync for stable and accurate operation

License validation

license.vemcogroup.com

443

License checks and validation

TDI setup note: In the official TDI integration guide, Vemcount specifies Server Address:data.vemcount.com, Server Directory:/ss/tdi, and port 80 for HTTP or 443 for HTTPS. The guide also recommends using XML instead of JSON if special characters or spaces may cause push-format issues.

Additional setup notes

  • In the TDI sensor, go to Server Config and enter the Vemcount server details.

  • Use the sensor's Test Setting function to confirm that the push connection works.

  • If JSON formatting causes issues, switch to XML as recommended in the official guide.

Main Vemcount IP addresses