The Cue Lists can be directly controlled using the global OSC Commands. This allows direct control over the cue lists without defining a Hardware Controller.
This is a great option if you can define specific commands on the sending device. (like Qlab or TouchOSC etc)
Available OSC Commands
/Cue/Recall [List number (text)] [Cue number (text)] | Recall a cue from a specific cue list |
/Cue/Recall [Cue number (text)] |
|
/Command/CueLists/FireNextCue |
|
/Command/CueLists/FirePreviousCue |
|
/Command/CueLists/StepUp |
|
/Command/CueLists/StepDown |
|
/Command/CueLists/GoToTop |
|
/Command/CueLists/StopAllCues |
To enable the global OSC commands, go to:
Options > Project Options > Osc Control
.
- Enable OSC Control
This turns on/off the sending and receiving of OSC commands. This does not affect any Hardware Controllers added, but it does affect the triggers in the Cue Lists.
- Input Port
The UDP network port that LiveProfessor will listen for OSC Messages on. This should match the port set on the sending device.
- Output Port
LiveProfessor uses this port to send information back to the controller to make it able to display the current state.
- Local Ip Address
This is a list of local IP Addresses found on the system. This is just for convenience and can be used to enter the correct address in the sending device.