PLATFORM MAINTENANCE
General
Viscosity unit conversion and unit consistency in calculators and search have been fixed.
Curve export data, configuration logic, and pricing validations have been refined for improved accuracy across all product families.
Bell & Gossett (B&G) Products
TechnoForce e-MTX:
The Solver application now defaults to 3-phase power for all configurations, and the product code automatically updates based on the selected impeller curve to ensure accurate setup and selection.
Goulds Water Technology (GWT) Products
e-SV Series:
Motor allocation updated for 3SV15GH4F60 as per the latest technical brochure.
Dimension data updated for 10SV13GK4E60 and 46SV11NH4F60 models.
Minimum motor power allocation updated for all GWT e-SV models.
Standard motor rating for 33SV (1750 RPM) updated to 1 HP in line with documentation.
e-SVI Series:
Material and product code updates applied to the 33, 46, 66, and 92 series — only Cast Iron (“G”) casing is now available, and the material code has been standardized to “G” (previously “N” was also available). Other pump sizes remain unchanged.
Lowara Products
e-HM Series:
e-HM items with plastic impellers will be phased out.
For three-phase 60 Hz models, motor selection updated per the latest technical brochure.
Single-phase 60 Hz e-HM pumps with IE2 motors are now available for full configuration in Solver.
e-IXP Series:
The impeller diameter is now visible when Installation: Liquid Pump is selected.
Product code for e-IXP ATEX updated as per the latest technical brochure.
e-LNT Series:
Motor allocation updated in accordance with the latest technical brochure.
e-MT, e-MTX, e-HVX, e-HVXR Series:
Solver logic has been updated to enforce the maximum allowable working pressures, ensuring only valid pump configurations are selectable.
e-NSC Series:
Dimensions updated for e-NSC 200-315 and e-NSC 250-315.
Variable speed curve limit increased from 50 Hz to 60 Hz.
e-SV Series:
Exported curve data now includes P1 input power and overall efficiency.
The 66SV2GH110T pump is now available with complete pricing.
PN rating added to dimensional data and included in downloadable datasheets.
e-SV Hydrovar X Series:
Temperature range updated from –30 °C / 180 °C to –30 °C / 120 °C, as high-temperature and boiler versions are not available.
e-SVI Series:
e-SVI and e-SVIE extended shaft versions will be phased out from the system.
GEM Series:
Accessories for Lowara GEM firefighting groups have been added and are now available in Solver.
GHV Series:
VFD Selection Update: For GHV30/10SV04 (2900 rpm), the HVL2.015 – 1PH 208–240 V Hydrovar is now selectable. Solver automatically chooses 1PH × 230 V and updates the last letter of the product code to “2”.
GHV HVX Series:
Configuration changes implemented for the Lowara GHV HVX+ Smart Controller range.
MPV Series:
Missing motor height dimensions have been added.
VM and VME Series:
These models have been disabled and are no longer available in Solver.
Z Series:
When “Include Cooling Set Shroud,” “Filter,” or “Brackets” are selected, their dimensions now display correctly in Solver.
Xylect Phased Out
The legacy Xylect application will be retired on November 30th. Transition to the new Solver application is required to ensure continued access and to leverage its enhanced features and improved adaptability. Learn more.