Setup Instructions:
Connect a 12V power supply to the 3 pole Euroblock connector or 5V power supply to either of the USB ports.
Plug the serial computer cable (TSI # 054-715) / RS-232 cable into the QuestTemp's RS-232 port.
Connect the other end of the cable directly to the Thiamis 1000's RS-232 port.
Note: QuestTemp must be added first and is only available for port A since it is powered by the Thiamis. It can not be added to port B or C.
Errors
When the QuestTemp is not reporting, check the configuration page or hover over the red status indicator for more information.
Timeout
The QuestTemp has not responded to the requests made by the Thiamis and has timed out. It will continue to attempt communication but you can run through the general Troubleshooting Sensors steps to address common problems.
Heat Index
List of Supported Models:
Click on names for links to manufacturer user manuals.