This article discusses what to check for if you're experiencing any issues related to the Touch Screen Monitor on a VAC kiosk equipped with a touch screen:

Touch Screen issues normally result in 1 of 3 symptoms:

  • Touch Inputs no longer being registered

  • Nothing at all is being displayed on the screen

  • The incorrect image is being display, or the correct image is displayed incorrectly (displaying colours incorrectly for example)

In most cases, a touch screen issue will be paired with an error code being shown in the VAC's status on the LaundroPortal:

If a VAC status error is present, troubleshoot the issue by following the steps for the specific VAC Status error you're seeing:

If no error is shown, follow the steps based on the touch monitor's symptoms:


Symptom: Touch Screen is showing a completely blank/black image

A monitor that is completely blank/black indicates that the touch monitor is either powered OFF, or is not getting an HDMI input signal to display on the screen.
​
First thing to check is if the Touch Monitor is powered ON.

Check the Power LED light on the back of the monitor itself.
​

Open the Value Add Center and locate the monitor's status LED on the top of the monitor itself.

Depending on the version of your monitor, this status light will appear in a different spot at the top of the monitor:

  • On version 1 monitors, the LED faces outwards (towards the back of the VAC):

  • On version 2 monitors, the LED and buttons face upwards (towards the ceiling):

    selectedImg
    selectedImg

When the monitor is working correctly, this status LED should be solid GREEN at all times (when the monitor is powered ON the status light goes GREEN, and should stay GREEN if it's receiving an HDMI signal).

- If the Monitor's status LED is completely OFF

This normally indicates a Touch Screen Power issue.

Press the power button on the Monitor to see if the Monitor's status LED turns ON.
​

If the LED goes GREEN and stays GREEN, check the monitor to see if it's now displaying an image correctly.

If the LED remains OFF when pressing the power button;

Confirm that the 12Vdc jack from the monitor's power supply adapter, is plugged into the back of the monitor securely;

and that the power supply itself is plugged into the VACs power bar securely:

selectedImg

If the monitor's power supply is plugged in correctly, and the monitor's status LED remains OFF when pressing the power button;

it's likely the monitor's power supply is faulty, the power bar plug it's using is faulty, or the monitor's power input has suffered a hardware issue.
​

- If the Monitor's status LED is solid RED

This normally indicates the monitor has powered itself off.

Try turning the Monitor back ON, by pressing the power button on the top of the monitor

(usually the middle button, beside the status light itself; but some models may have the power button on the far right side - the power button will be labeled with the power symbol ""):

selectedImg

Once you've trigger the touch screen monitor to power back ON, observe the monitor's status LED to see what it's doing.

If it turns solid GREEN and stays like this, check to see if the monitor is now working correctly.

If it turns some other colour, or starts flashing, follow the steps based on the status LED state.

- If the LED is flashing RED

typically indicates a Monitor hardware issue

this typically indicates a hardware problem with the control board inside the monitor itself.
​

Try doing the reset procedure details in the "If the LED is flashing GREEN" section to see if that helps resolve the issue.

If not, contact our support team for troubleshooting help with this issue.

- If the LED is solid GREEN

typically indicates a Monitor software issue

If the LED is solid Green, yet the screen is still blank/black, it is likely a software issue.

Try rebooting the Value Add Center (unplug power for 2 seconds, then plug the power back in).

Allow the VAC a couple minutes to boot back up, then check the LaundroPortal to see if you have any error messages related to either the VAC being offline, or an error message related to the touch monitor itself (see below for a few examples):

​


If the monitor's status light is GREEN, but there is still no image AND you're seeing an error message on the LaundroPortal, you'll want to troubleshoot the LaundroPortal error first, as this could be the reason the touch monitor isn't displaying any output.

If there is no error message in the VAC status, try using a laptop (or some other device that can output an HDMI signal, and plug the monitor into a working device to see if it will display an image.

If the touch monitor can't display any image from a laptop (or some other device) with a known working HDMI output, then the monitor has suffered a hardware issue and will need to be replaced.
​
If some other HDMI equipment can display an output on the touch monitor, but when connected to the VAC it does not display an output; it could mean there's an internal VAC setting that needs to be enabled, or there's an issue with the VAC control board's HDMI output. Contact our support team for help troubleshooting a VAC board HDMI output issue.

​

- If the LED is flashing GREEN;

typically indicates a Monitor hardware issue

This could indicate a hardware problem with the display control board inside the monitor itself.
​

Try resetting the monitor by doing the following:

  1. Press and hold the Power button on the monitor for 10 seconds:


    Once you press the power button, that status light may change colours, but continue holding the power button for the full 10 seconds.
    ​

  2. Unplug the power cable from the monitor:


    After holding the power button for 10 seconds, unplug the monitor's power cable and leave it unplugged for about 10 seconds.

  3. Plug the monitor's power cable back in, and check the monitor's status light to see what it's doing:

    1. If the Monitor's status light is now a solid GREEN, check to see if the monitor is working correctly again.

    2. If the Monitor's status light is now a solid RED, press the power button once to turn the monitor ON.

    3. If the Monitor's status light is still flashing either colour, you can try the reset procedure one more time, but this likely indicates a hardware issue with the monitor itself.
      ​

After performing the above reset procedure, if the monitor's status light is still flashing, either RED and GREEN; this usually indicates an issue with the monitor itself, and the touch screen monitor will need to be replaced.


VAC Status Error: "Touch Monitor - HDMI connection not detected"

This error is usually related to an issue with the HDMI cable connecting the touch monitor to the VAC control board:

Make sure the HDMI cable is fully plugged in to both the Monitor and the VAC's HDMI port.

If the cable is plugged in correctly, try re-seating this cable by unplugging it on both ends, and plug it back in to reseat the cable; then power the VAC OFF for 2 seconds, then back ON to see if that corrects the issue.
​

If the error remains, this usually indicates there's an issue with the HDMI cable itself.

Replace the HDMI cable with a known working cable and test to see if that clears this error message (reboot the VAC after replacing the HDMI cable).
​

  • If the error remains when using a known working HDMI cable
    unplug the HDMI cable from the VAC control board, and plug this cable into a laptop (or any equipment that can provide an HDMI output), to see if the monitor can output an image from a known working HDMI source.
    ​

  • If the monitor CANNOT output an image from a laptop with a known working HDMI source then there is likely an issue with the touch monitor itself.
    ​

  • If the monitor IS able to display an image from a laptop with a known working HDMI output then there is likely an issue with the VAC control board's HDMI output.

Contact our support team for additional troubleshooting help.


VAC Status error: "Touch Monitor - USB Touch not detected" or Touch Inputs not being detected at all

This error is usually related to an issue with the USB cable that connects the touch monitor to the VAC control board:

Note: If you have a touch monitor with the label "Monitor T2" this is a slightly different version of the version 2 monitors:

  • "Monitor T2" touch monitor's will use a USB Type A to USB Type A cable for touch input detection:

  • Unlabeled touch monitor's will use a USB Type A to USB Type B cable for touch input detection:

Try re-seating this USB cable by unplugging it from the touch monitor, and plugging the cable back in.
You will also want to re-seat this USB cable where it plugs into the VAC control board.

(it will be plugged into 1 of the USB ports on the VAC control board itself - the specific VAC USB port you're using does not matter):

Once you've re-seated this USB cable, reboot the VAC kiosk (unplug it from power for 2 seconds, then plug the power back in).

Once the VAC boots back up, check to see if the error message has cleared, and if the touch inputs are working again.
​

If the error is still present, or touch inputs still aren't being registered;

try using one of the other available USB ports on the VAC control board (if they're all populated, simply swap the USB cables so the touch monitor's USB cable is using a different VAC USB port).

Then reboot the VAC again and check to see if that's corrected the issue.
​

If the error is still present, replace the USB cable with a known working USB cable, and then reboot the VAC to see if a working USB cable has corrected the issue.

If touch inputs still aren't working, confirm you're using the correct power supply to power the monitor:

The VAC control board's power supply is extremely similar to the Touch Monitor's power supply, and they use the same type of plug which will fit in either component.

Check to confirm you haven't accidentally swapped the power supplies between these 2 components, especially if you've recently replaced the monitor or VAC control board, as that will cause both to intermittently exhibit strange behavior:

If you're still running into the same issue, when using a known working USB cable, you've tried different USB ports on the VAC control board, and confirmed you're using the correct power supplies;

it's likely the issue is being caused by the internal USB port on the touch monitor itself, and the touch monitor would need to be replaced to correct this issue.


While it's possible the issue is being caused by the VAC control board; the VAC will typically also be using it's USB ports to communicate with your receipt printer. If the receipt printer is working correctly, then you'll know the USB port it's connected to is working correctly; if that USB port does NOT work to allow touch inputs to be registered, then you'll know the touch screen monitor is the cause of this issue.


VAC Status error: "Touch Monitor Software Output Error (check monitor)"

This usually indicates there's an internal error related to the system controlling the touch monitor.

Try rebooting power to the kiosk. If the problem persists after the reboot, try pushing a VAC software update to this specific VAC, via the VAC Command's page (CMD button for this specific VAC):

If the problem persists after a VAC power cycle and a VAC software update, the issue is most likely cause is the touch monitor itself; however it is recommended to contact our support team for additional troubleshooting help with this error.


VAC Status error: "Touch Monitor controller box not detected"

You will typically only see this specific error, if your VAC is equipped with a VAC3 (1st generation) control board.

These control boards use an external touch Monitor Controller to control the output to the touch monitor (unlike the newer VAC4 control boards, which have the monitor controller built into the main control board itself):

Below are a couple of pictures showing what the external touch monitor controller looks like:

Inspect the Monitor Controller to confirm it's powered ON (there should be a RED status light showing if it's receiving power correctly).
​

The Monitor Controller receives power from a USB cable just below the power LED status light:

- If the Monitor Controller has NO power indicator showing

check monitor controller's USB POWER cable

check the USB power cable to ensure it's plugged into power correctly.
​

If it's connected to power, but the power indicator is still not illuminated, this generally indicates an issue with the power USB cable, or a hardware issue with the monitor controller itself. Try using a different USB-B cable.
​

If a known working USB cable still doesn't power ON the monitor controller, the VAC control board will likely need to be replaced (the new generation VAC4 control board's have the monitor controller built into it).
​

- If the Monitor Controller's power indicator IS illuminated

check monitor controller's DATA USB cable

check the USB DATA cable to ensure it's plugged into 1 of the VAC control board's USB Ports:

​

If the USB Data cable is connected correctly, try moving it to the other USB port on the VAC control board (if the other port is populated, simply swap the USB cables between the 2 ports.
​

If swapping the USB ports does not correct the issue, it's likely there's an issue with the data USB cable, or the monitor controller has suffered a hardware issue.
​

Try using a known good USB cable to connect the Monitor Controller to the VAC control board.

If that doesn't correct the issue, it's likely the Monitor Controller has suffered a hardware issue, and the VAC control board will need to be replaced (the new VAC4 control board's have the monitor controller built into it).


VAC Status error: "Touch Monitor - Entirely not detected"

This error indicates that the VAC control board is unable to detect that a touch monitor is connected to it (it can't detect the touch monitor's USB connector or it's HDMI connection).

First try rebooting the VAC kiosk to see if that corrects this issue.
​

If the error remains after the reboot, check the Monitor's USB cable, and HDMI cable, to confirm that both cables are connected to the VAC control board correctly:

  • If the cables were NOT connected correctly
    connect both the USB and HDMI cables correctly, then reboot the VAC and check to see if the error has now cleared.
    ​

  • If the cables ARE connected correctly
    Try pushing a VAC software update to the VAC via the LaundroPortal's remote command's page (CMD button for this specific VAC):


    Once the VAC software update has completed, the VAC will reboot automatically.
    After the reboot, check to see if the error has cleared.
    ​
    If the error persists, contact our support team for additional troubleshooting help for this specific error.


​

Issue: the Monitor image flickers occasionally, or shows issues with image color/image consistency

These issue are usually the result of either a bad HDMI cable, or a hardware issue with the touch monitor itself.

First try using a known good HDMI cable to see if that corrects the image issue.
​

If the issue persists, try using a laptop (or any other equipment that can provide an HDMI output), to see if the touch screen image issue is the same when providing the monitor with an HDMI output from a different HDMI source.
​

If the screen also has the same issue when a different, known working HDMI source, is providing the HDMI output; then the issue is with the touch monitor itself, and it will need to be replaced.
​

If the image issue only happens when the monitor is connected to the VAC control board, and you've already tried using a known working HDMI cable;

it's likely the issue is with the VAC control board's HDMI output. Contact our support team for additional troubleshooting help for this issue.


Issue: The screen says "Loading...."

This is a very rare issue that usually indicates that some piece of software may have frozen.

Try rebooting the power to the Value Add Center.
​

If that doesn't correct the issue, take a photo of the internal connection of the Value Add Center and send them to our support team for analysis.


Issue: Touch events are delayed

To clarify the observation - it takes a few seconds for the screen to change or respond whenever you make some selection on the screen.

The delay would be strictly related to reacting to touch inputs.

However, if you place an existing Laundry Card onto the VAC's Card Holder, the screen responds and changes to display the card's balance quickly, and when you then remove the Laundry Card, the screen responds and changes back to the home screen quickly.

If this is observed, then there is no issues with the VAC's responses being delayed - the delay is only present when reacting to touch inputs.

If this is the case, then this should be resolvable through a remote software update. Please contact our support team about this issue so we can push a software update to the VAC.

As a temporary fix, power cycling the VAC will force it to reload it's touch software which can speed up touch event response times until your VAC software can be updated.


​

Issue: Everything is delayed

To clarify the observation - changes to the screen are delayed in all cases (whenever the screen is reacting to touch inputs, or when the screen is reacting to a Laundry Card being inserted into the VAC's card holder, or when a bill is inserted into the bill acceptor).
​

This issue may be related to a hardware issue related to a particular production batch.
​

Contact our support team to troubleshoot this specific issue.


Issue: Screen just shows the Laundroworks logo

You can reboot the Value Add Center (manually by unplugging power for 2 seconds, then plugging the power back in), or through the LaundroPortal's remote commands:​

​

If your VAC is equipped with an external touch Monitor Controller, or a VAC3 control board; it's possible this issue is being caused by 1 of these 2 components:​

If rebooting the VAC kiosk doesn't correct this issue, or you're VAC is equipped with any of the 2 above components, contact our support team for additional troubleshooting help for this issue.