Skip to main content

Solar Rules

Check that open space gets enough sun

Written by Holly Conrad Smith

Many planning codes ask for a share of open space to get a minimum amount of sun, such as 2 hours on 50% of communal open space at the winter solstice. Solar rules check this for you. Each rule shows Pass or Fail as you change your design, so you know where you stand before you submit.

How solar rules work

A solar rule checks that enough of the landscape with the usages you pick gets sun. Each rule has three values:

  • Minimum sun: the hours of sun a point needs to count as sunny. It starts at 2 hours and goes up to 12.

  • Required share: the share of the area that needs the minimum sun for the rule to pass. It starts at 50%.

  • Required area: an area that is enough on its own. The rule passes when this much area gets the minimum sun, even when that is less than the required share. Use it for rules such as "50% of the open space, or 250 m², whichever is less". Set it to 0 to turn it off.

Rules check the landscape only. The Baseline sets the minimum sun for everything no rule covers, such as facades and the rest of the ground. Rules and the Baseline are saved with the project, so everyone on your team checks against the same rules.

Add a solar rule

  1. Open the Solar app and click Sun hours at the top.

  2. Click + beside Rules. Solar adds a rule named "New rule" and opens the Rules tab in Solar settings.

  3. Type a name for the rule, such as "Communal open space".

  4. Click the Landscape usages box and pick the usages the rule covers. The box lists landscape usages only.

  5. Set Minimum sun, Required share, and Required area.

  6. Close Solar settings. The rule shows under Rules with a Pass or Fail tag.

OR

  1. Click the settings button at the top of the Solar app and pick the Rules tab.

  2. Click New Rule.

Read a solar rule's result

Under Rules in Sun hours mode, each rule shows a green Pass or red Fail tag and a summary line, such as "62% of 1,200 m² gets at least 2 h (needs 50%)". When Required area sets the bar, the summary shows the area the rule needs instead of the share. Click a rule to open it in Solar settings.

Some rules show a message instead of a result:

  • "Choose the usages this rule covers." means the rule has no usages yet.

  • "No landscape has these usages." means no landscape geometry in the project uses the rule's usages.

  • "Turn on Sun hours to check this rule." shows in Solar settings while Sun hours is off.

Set the Baseline

The Baseline is the minimum sun for facades, the rest of the ground, and any landscape no rule covers. It starts at 3 hours. To change it, click the settings button at the top of the Solar app, pick the Rules tab, and set Baseline.

The Baseline sets the Sunny share for Other ground and Facades in Results, and the Pass/fail colors for those surfaces.

When two rules cover the same usage

When two solar rules cover the same landscape usage, the Pass/fail colors and the Landscape features table use the rule with the higher Minimum sun. Each rule still shows its own Pass or Fail tag.

Delete a solar rule

Click the settings button at the top of the Solar app, pick the Rules tab, and click the trash button on the rule.