Value Add Center (VAC)-related error messages

VAC errors can be presented either on the VAC's display, or on the VAC status on the LaundroPortal. In most cases, if an error is displayed on the VAC's display, there is also an error being displayed in the VAC status of the LaundroPortal.

When errors are present in both places, it is always recommended to troubleshoot the issue based on the VAC Status error shown on the LaundroPortal:


Value Add Center Status Messages (as seen in the VAC Status section of the Portal):

VAC Status Message

Description/Solution

These bill acceptor errors are described in detail in our Bill Acceptor Issues article.

Use the table of contents in the above article to jump to the troubleshooting section for the specific error you're seeing, or click on the specific error in the table to jump to that section of the article.

Cant enable bill acceptor

The system is not able to enable the bill acceptor when a user places the Laundry Card into the VAC card holder, or attempts to purchase a new Laundry Card.

Check to ensure that the cash box of the bill acceptor is not full, and check to make sure that the lower housing of the bill acceptor does not have any crumpled up bills, or debris, blocking its sensors.
​

If you checked the cash box, and lower housing, and the message persists, contact our support team for troubleshooting help.
​

For more information see the Bill Acceptor Issues article.

Card dispenser jam or out of order

Remove all cards from the dispenser and check to make sure there are no cards jammed in the dispenser, or the slot where the dispenser pushes out new cards.

Check wiring connection from the card dispenser to the VAC Control Board, to make sure there are no loose connections.
​

Card dispenser - loose card detected

This message indicates the card dispenser is detecting a loose laundry card in, or around, the area where new laundry cards are dispensed. This loose card is interfering with the ability of the card dispenser to dispense new cards.
​

  • Card reader 1 error

  • Card reader 1 error (NFC init error)

  • Status_CR1:8

Card reader 1 is the NFC/RFID reader that reads/writes information (such as card balances) to Laundry Cards that are placed in the VAC's card holder.

This error results in the inability for users to add value to existing Laundry Cards.

  • Card reader 2 error

  • Status_CR2:8

Card reader 2 is the NFC/RFID reader that reads/writes information (such as card balances) to Laundry Cards as they are dispensed.

This error results in the inability for users to purchase new Laundry Cards.
​

Low disk space: ##

This message does NOT indicate a problem with your system. If you see a Low disk space message, it means the memory on your VAC control board is running low.
​

This can happen during a software update: sometimes the VAC doesn't delete all of the old files after the software update is complete.
​

Your system will operate without issue when this message is present.

If you see this message, please contact our support team so we can clear all the unused files from your VAC's memory.

More than 5 consecutive non-approved Credit/Debit sales (see VAC Log)

This is a warning message that indicates you could have a problem with the payment terminal, or with its configuration. However, you will also see this message if a customer has an issue with their credit/debit card that is unrelated to your system (wrong PIN, insufficient funds, customer manually aborts the transaction, etc.).
​

Any 5 consecutive non-approved transactions will trigger this warning.
​

Under the Reports section, look at the VAC Log report to review the transaction records for the last 5 transaction attempts:

  • If this problem is happening to the same customer, chances are it is a problem with that customer's credit/debit card or their bank account.
    ​

  • However, if transactions are declining for many different customers, then it is possible you have an issue with the PINpad terminal, or the configuration of it.

This bill acceptor error is described in detail in our Bill Acceptor Issues article.

Use the table of contents in the above article to jump to the troubleshooting section for the specific error you're seeing, or click on the error in the column on the left to jump to that section of the article.

PAX BroadPOS not responding (re-install)

Case 1 - If this is a new installation:

  1. This error message should only be shown if your VAC has a PAX PINpad terminal installed. Either a PAX S300, or PAX A35. If you have a Stripe PINpad terminal installed (P630, or S700) the VAC settings are incorrect. Contact our support team to have the VAC settings reconfigured for Stripe terminals.
    ​

  2. It is likely the actual payment software that runs on the terminal itself (Paygistix when Fortis is the payment processor) is not currently running on the new PINpad terminal.
    ​
    If your PINpad terminal is showing a bunch of Android app icons on the screen, click on the Paygistix app icon to open the payment app.
    ​
    See article: Installing PAX A35 PINpad (Credit card terminal) - US Customers for more details.


    If you don't have the Paygistix app on the terminal, it's likely the terminal has not yet been activated to use the merchant account created for the store.


Case 2 - If this is an existing PINpad that was previously working correctly:

  • It is possible that the payment application crashed, or froze up.

    • For PAX S300 PINpad terminals:
      ​
      Try power cycling the PINpad terminal (unplug power to it for 2 seconds, and then plug power back in), or you can power cycle the entire VAC kiosk.
      ​
      You may need to wait up to 10 minutes after the reboot before the PINpad software syncs back up with the VAC software again.
      ​
      See article: Credit Card Processing Issues (US Customers) for more details.

    • For PAX A35 PINpad terminals:

      First try power cycling the PINpad terminal (unplug power to it for 2 seconds, then plug the power back in), or you can power cycle the entire VAC kiosk as this should also cut power to the terminal.
      ​
      If you're still seeing this error after power cycling (and waiting 10 minutes for the payment software to sync with the VAC software), it may indicate a hardware issue with the PINpad terminal itself. Contact the Laundroworks Support team so we can ensure it's running the latest Paygistix payment App software version.

Payment terminal error

Case 1: This terminal was working before:

  • Reboot PINpad by disconnecting and reconnecting the power to it, or by rebooting power to the entire Value Add Center. Wait up to 15 minutes.
    ​

Case 2: This is a new location:

Payment terminal not detected

There's no communication between the PINpad (credit card) terminal, and the VAC control board.


​Case 1 - This terminal was working before:

  • Step 1: Check the screen of the credit card terminal. Confirm it is powered ON and not displaying any error messages. If it's OK (showing the normal idle screen), go to Step 2.
    ​

  • Step 2: Reboot power to the terminal by disconnecting and reconnecting the power to it, or by rebooting power to the entire Value Add Center. Wait up to 15 minutes.​


Case 2 - This is a new location:

Payment terminal not detected (no ethernet connection)

This is a variation of the "Payment terminal not detected" error; however, the "(no ethernet connection)" message indicates that the VAC control board is not detecting anything that's potentially plugged into the VAC's AUX1 port (the Ethernet port the VAC uses to communicate with connected PINpad terminals).

Payment terminal software/App problem

Case 1 - If this is a new installation:

Case 2 - If this is an existing PINpad that was previously working correctly:

  • It is possible that the payment application crashed, or froze up.
    Try power cycling the PINpad terminal (unplug power to it for 2 seconds, and then plug power back in), or you can reboot the entire VAC kiosk.
    ​
    You may need to wait up to 10 minutes before the PINpad software starts communicating with the VAC software again.
    ​
    See: Credit Card Processing Issues (US Customers) for additional information.

Printer out of order

Check the connection between the printer and the VAC control board. Also check to ensure that the printer is connected to a 24V power supply, and that the printer's power switch is in the ON position.

You will also want to check for a flashing red error light on the printer itself. If this light is flashing, use the troubleshooting table found at the bottom of this article to decipher which error code your printer is displaying.

If the card dispenser was replaced recently, and was changed from an Asahi-Seiko, to a Syncotek card dispenser, the "Printer Receipt" setting in the VAC settings may have to be changed from "Serial Printer" to "USB Printer". Syncotek card dispensers must use the serial port that the receipt printer may have been using previously.

In these cases, the receipt printer should be connected using a USB port on the VAC control board, instead of the serial cable.
​

For more information see: Receipt Printer Issues article.

Printer out of paper

This error will be present if the printer is unable to detect that receipt paper is installed.

This usually indicates the receipt paper roll is out of paper, but could also indicate the receipt paper sensor is dirty or defective.

See our Receipt Printer - VAC Status printer errors article section for detailed troubleshooting steps.

Touch Monitor - HDMI connection not detected

This error can be caused by one of three things:

  • issue with the touch monitor's HDMI input port

  • issue with VAC control board's HDMI output port

  • issue with the HDMI cable connecting the monitor to the VAC control board

In most cases, the issue will be with the HDMI cable. It's possible the HDMI cable needs to be replaced, or is not fully plugged into the VAC control board, or touch monitor's HDMI port.

Ensure the HDMI cable is fully plugged in on both ends, and try replacing it with a known working HDMI cable to see if that corrects this issue.

See our Touch Monitor Issues - HDMI connection not detected article for troubleshooting details.

Touch Monitor - USB Touch not detected

Check the USB cable connecting the VAC Control Board to the touch monitor.

Usually reseating or replacing the USB cable can resolve the issue; however, see our Touch Monitor Issues article for more troubleshooting details.

VAC Offline

See our article on: VAC Offline and Internet Issues for more information on how to troubleshoot this specific error.

Warning: Payment terminal license screen (click ? for more info)

The PINpad terminal connected to this VAC is currently showing its license agreement screen.

This usually occurs if the software running on a PAX A35 PINpad terminal has been recently installed/re-installed.

Someone on location will need to accept the license agreement on the PINpad itself to correct this issue.

See the Fixing the PAX A35 terminal License screen article for more details.

WNC error

There's no communication between the Wireless Network Controller (WNC) and the VAC control board.
​

The WNC on the primary Value Add Center (VAC01) is responsible for wireless communication with the card readers.
​

See: WNC Issues article for troubleshooting steps.


Card Reader related error messages

Card Reader errors can be presented either on the Card Reader's display, or on the Machine list for that specific Card Reader on the LaundroPortal. In most cases, if an error is displayed on the Card Reader's display, there is likely also an error being displayed in the Machine list on the LaundroPortal.

When errors are present in both places, it is recommended to troubleshoot the issue based on the error message seen in the Machine List on the LaundroPortal:


Card Reader Messages (as seen on the physical reader's display):

Message on Reader's Display

Description/Solution

ACCESS DENIED Code: A01

This message will be displayed if:

  • you are placing a Laundry Card (Management or regular card) on a reader that has not been activated yet.
    ​
    Activate the reader with the Activation Card for this specific store location, then test it out again.
    ​

  • you're trying to use a Laundry Card from a different store location (different store location ID or Support ID)
    ​

  • the store was recently migrated to a new account, and the Laundry Card being used hasn't been reprogrammed by the VAC kiosk for the store's new Support ID/Location ID.

BALANCE TOO HIGH

All Card Readers have a "Balance Limit" setting that sets the maximum balance a Laundry Card can have when interacting with that specific Card Reader.
​
By default, Card Readers are now set to the absolute maximum balance limit of $655.35. However, older card readers had their maximum balance limit set to either $300 or $100 by default.
​
If you've recently made changes to your reload bonus configuration, and are now seeing this error message, it's likely the Card Reader that's showing this error is still using the old balance limit default setting.

*Blank Screen (Only the green backlight is ON)

*This is not a message that will be displayed on the reader's screen, but a description of what the reader's screen may look like.
​

If you have a reader that powers ON (green backlight is visible) but there is no text on the screen, it is likely that this reader has experienced a hardware failure and will need to be replaced.

In Bootloader

See: Reader says "In Bootloader" article for more information.

Joining Netwk...Can't Join!

The reader is unable to communicate with the wireless network gateway inside the Value Add Center (in VAC01). See: Reader says "Can't Join" article for more info.
​

This is usually the result of:

  • VAC01 not being powered ON

  • the reader was activated with a different location's Activation Card

  • there is a WNC error on VAC01.

  • there is wireless interference in the location​

If you are also seeing a WNC error in VAC01's VAC status (on the LaundroPortal), resolve that issue first and then see if the reader is able to join the network successfully.

MACHINE ERROR

This is indicating a problem with the machine, NOT an issue with the Card Reader.


The machine (washer/dryer) is telling the reader that it is experiencing some kind of machine error.

Check the machine for any abnormal behavior, or any error codes on the machine's display itself.

Once the error on the machine has been cleared, the Card Reader's "Machine Error" message will clear on its own as well.

No Comm With Machine

The Card Reader is unable to communicate with the machine using serial communication, or the machine and reader are out of sync.
​

Either the machine is set to Pulse mode, while the reader is trying to use Serial communication, or the reader and machine are both trying to use serial communication but are unable to establish communications.
​

Check the screen on the actual machine to figure out if the machine is set to serial.
​(E.g. an EC18/EC19 error on an Alliance machine means the machine is configured for serial communication mode, but it is not able to communicate with the reader.)
​

Consult the reader installation article, for your specific machine type, to find out how to set your particular machine into serial communication mode.
​

If you know that your machine should be set up for pulse mode, then the reader should also be set to the correct pulse control type.

Contact our support team if you don't know which control type your machine should be using.

NOT ACTIVATED

The Card Reader is in factory default.

Simply place your location's Activation Card on the reader to activate, and configure, the reader.

Activation Cards are specific to each Support ID AND Location ID, so ensure that you are using the correct Activation Card for your location.
​

If you don't have an Activation Card, or have misplaced it, you can convert a regular user card into an Activation Card using the LaundroPortal.

RFID Error

The reader is unable to communicate with the RFID/NFC circuit board on the card reader's electronic assembly, and as a result it will not interact with any Laundry Cards/Mobile App accounts.
​

An RFID error can occasionally be resolved by power cycling the reader (unplug power to the machine for 5 seconds and then plug power back in).
​

If a power cycle doesn't resolve the issue, or if this reader displays an RFID error frequently, please contact our support team; we can deploy newer firmware which can resolve this issue in some cases. See the RFID Error article for additional information.

  • UNAUTHORIZED Code: B01

  • UNAUTHORIZED Code: B02

Both versions of this message mean essentially the same thing. This is the message that will be displayed if a banned card is placed onto a Card Reader or VAC kiosk.


Card Reader Status Messages (as seen in the Machine Status section of the Portal):

Machine Status Message

Description/Solution

Check if machine exists. Remove this row if not.

When a reader has been offline for an extended period of time, especially during a new installation, the normal "Timeout - check reader/machine" message will turn into this message.
​

If this reader/machine no longer exists in your location, you can safely delete this reader from the LaundroPortal's Machines list by clicking the "X" icon.
​
If the reader does exist, first confirm VAC01 is online, and power cycle the card reader. If it's still showing the same message, review our offline Card Reader article for troubleshooting steps.

Machine Error

This is indicating a problem with the machine, NOT an issue with the reader. The machine (washer/dryer) is telling the reader that it is experiencing some kind of error.
​

This error will sometimes be followed by a description of the type of error the machine is experiencing. (E.g. "Drive Board Error", "Output Board Error", "Drain Error", "Door Lock", "Door Open", "Fill Error", "No Water Flow", etc.)
​

Check the machine for any error codes, or abnormal behavior.

Once the error is corrected on the machine side, the Card Reader's Machine Error will clear on its own.

Machine/Serial Communication Error

If you've just replaced the reader, and are now seeing this message, check to make sure you have the correct reader board for that machine:

  • On the back of the reader board you will find a sticker that says what type of reader board it is (e.g. "Generic Serial", "Compass Serial", "Voltage Relay", etc.). Make sure the new reader board you are using is the same type of reader board as the one you are replacing.
    ​
    Next you'll want to check the Control Type (from the LaundroPortal).
    In the reader's "Machine Configuration" settings (click reader's gear icon), check to ensure it's using the correct Control Type for that machine. If you have another machine (of the same model type) that is working correctly, compare that reader's Control Type with the Control Type of the new reader you've installed. If the reader was using the incorrect Control Type, change the Control Type to the correct one, and then power cycle the machine (unplug power for 5 seconds, then plug power back in). If you've changed the control type but you're still seeing this message, the reader may require a firmware update. Get in contact with our support team and we will update that reader's firmware.

If those things are all correct, or if this is an existing reader that is suddenly displaying this message, you may have a machine issue. Try doing a swap test to confirm whether or not you have a reader problem, or a machine problem.

Consult the reader installation article, for your specific machine, for additional info.

Manual Mode

This does not indicate an issue with the Card Reader; this message means that the machine is currently in some kind of manual/service/programming mode.
​

Once the machine is returned to its normal operating mode, this "Manual Mode" message will clear automatically.

RFID Error

The reader is unable to communicate with the RFID/NFC circuit board on the card reader's electronic assembly, and as a result it will not interact with any Laundry Cards/Mobile App accounts.
​

An RFID error can occasionally be resolved by power cycling the reader (unplug power to the machine for 5 seconds and then plug power back in).
​

If a power cycle doesn't resolve the issue, or if this reader displays an RFID error frequently, please contact our support team; we can deploy newer firmware which can resolve this issue in some cases. See the RFID Error article for additional information.

Timeout - check reader/machine

This indicates that the Card Reader is not connected to VAC01's wireless network.
​

Make sure the machine is powered ON and the reader is getting power. If the reader's screen looks normal, try power cycling the reader (unplug power to the machine for 5 seconds, then plug power back in) and see if the reader has reconnected to the wireless network after the power cycle.
​

If you are still seeing this message after power cycling the machine, see article:
​

Timeout - check VAC

Make sure VAC01 is online.
​

See: VAC Offline and Internet Issues article for more information